S70 Bean Temp Thermocouple with M12 Connector
Part #:
1010021
Contents:
1 – S70 Bean Temp Thermocouple with M12 Connector
NOTE: If the thermocouple being replaced is a non-connectorized style the M12 connector upgrade kit (PN: 1010025) wiring must also be purchased to upgrade the roaster.
This M12 connector simplifies the removal of the bean discharge door and bean temp thermoccouple.
Used On / Where is it Located:
S70 Peregrine
Discharge Door
Parts Service Factor / Life Expectancy:
Life expectancy is dependent upon roaster usage. Symptoms indicating replacement needed include damage resulting from improper removal or usage or inaccurate bean temperature readings.
Note: A damaged thermocouple typically shows extreme temperature readings or a zero temperature. Improper positioning of the bean thermocouple can influence bean temperature readings without being damaged. Contact Loring support for instructions regarding proper positioning of the bean thermocouple.