Part #:
2013254
Description:
1 yellow K-type connector male
1 yellow K-type connector female
Used On / Where is it located:
All connected thermocouples on all loring roaters
Contents:
1 male yellow connector
1 female yellow connector
Parts Service Factor / Life Expectancy:
Life expectancy is dependent upon roaster usage. Symptoms indicating replacement is needed include damage resulting from improper removal or usage, or inaccurate bean temperature readings.
A damaged thermocouple typically shows extreme temperature readings or a zero temperature. Improper positioning of the bean thermocouple can influence bean temperature readings without being damaged. Contact Loring support for instructions regarding the proper positioning of the bean thermocouple.